面對數十上百台思科設備,手動逐台配置不僅低效且易出錯。透過 VanDyke SecureCRT 內建的 VBScript 引擎,即可將重複性操作(登入、進入配置模式、修改介面、備份 running-config 至 TFTP)封裝為可重複執行的腳本。本文以實戰案例逐行解析腳本邏輯與關鍵函式。
需求:對 10.1.1.1 設備以帳號 ccie/密碼 ccie 登入,關閉 FastEthernet0/1,並將 running-config 備份至 TFTP 伺服器 10.1.1.10。
#$language = "VBScript"
#$interface = "1.0"
Sub Main
' 開啟同步模式,確保逐字元等待提示字串,避免漏收資料
crt.Screen.Synchronous = True
On Error Resume Next
' 嘗試 Telnet 連線,失敗則重試一次
crt.Session.Connect "/telnet 10.1.1.1"
If Err.Number <> 0 Then
crt.Session.Connect "/telnet 10.1.1.1"
End If
' 等待登入提示並發送帳密(VbCr = Enter)
crt.Screen.WaitForString "Username:"
crt.Screen.Send "ccie" & VbCr
crt.Screen.WaitForString "Password:"
crt.Screen.Send "ccie" & VbCr
' 進入特權模式與全域配置模式
crt.Screen.WaitForString "Router#"
crt.Screen.Send "config t" & VbCr
crt.Screen.WaitForString "Router(config)#"
' 關閉介面
crt.Screen.Send "int f0/1" & VbCr
crt.Screen.WaitForString "Router(config-if)#"
crt.Screen.Send "no shutdown" & VbCr ' 範例為啟用,若要關閉請用 shutdown
crt.Screen.WaitForString "Router(config-if)#"
crt.Screen.Send "end" & VbCr
' 備份 running-config 至 TFTP
crt.Screen.WaitForString "Router#"
crt.Screen.Send "copy running-config tftp://10.1.1.10" & VbCr
crt.Screen.WaitForString "Address or name of remote host [10.1.1.10]"
crt.Screen.Send "" & VbCr ' 直接按 Enter 採用預設
crt.Screen.WaitForString "Destination filename [router-confg]"
crt.Screen.Send "" & VbCr
' 處理 "--More--" 分頁提示
Do While crt.Screen.WaitForString("--More--", 1)
crt.Screen.Send " " ' 送空白鍵翻頁
Loop
' 結束會話
crt.Screen.Send "exit" & VbCr
crt.Session.Disconnect
crt.Screen.Synchronous = False
End Sub
| 函式 | 用途 | 範例 |
|---|---|---|
crt.Screen.WaitForString(str, timeout) | 阻塞等待螢幕出現指定字串,timeout 秒後傳回 False | crt.Screen.WaitForString "Router#", 5 |
crt.Screen.Send(str) | 向會話發送字串,需自行附加 & VbCr 模擬 Enter | crt.Screen.Send "show run" & VbCr |
crt.Session.Connect("/telnet | 發起 Telnet/SSH/Serial 連線 | crt.Session.Connect "/ssh 192.168.1.1" |
crt.Session.Disconnect | 斷開當前會話 | |
crt.Screen.Synchronous | True=同步等待,False=非同步(預設) | 腳本開頭設 True,結尾設 False |
crt.vbs(編碼 ANSI/UTF-8 均可)。WaitForString 字串是否與實際提示完全一致(含空白、大小寫)。crt.Screen.IgnoreEscape = True 忽略 ANSI 色碼干擾。If crt.Screen.WaitForString("Error", 2) Then ... 記錄失敗設備清單。crt.Session.Connect "/ssh 10.1.1.1 22" 並處理金鑰指紋確認提示。腳本自動化不僅節省人力,更能確保配置一致性與留存審計軌跡。建議網管建立標準腳本庫,納入版本控管(Git),並定期演練災難恢復流程。